New Product Launch | P90 Series UV-Vis Spectrophotometer for Pharmaceutical QC — Upgraded Performance and Compliance
The PULY P90 Series UV-Vis Spectrophotometer is designed for pharmaceutical QC laboratories, combining high-performance dual-beam optics with comprehensive data integrity and compliance features. With audit trails, user access control, original data protection, intelligent management, and reliable analytical performance, the P90 Series provides a complete solution for pharmaceutical quality control, R&D, and regulated laboratory environments.
In pharmaceutical QC laboratories, drug R&D, and quality control, UV-Vis spectrophotometers are widely used for raw material and excipient testing, drug assay, method development, quality studies, and many other analytical tasks.
For pharmaceutical laboratories, instrument requirements are no longer limited to simply “Is the measurement accurate?”
Is the analytical data complete and reliable?
Can every operation be traced?
Can original data be retained over the long term?
Are changes to users, methods, and data fully documented?
These factors are becoming increasingly important in pharmaceutical quality management.
To address the pharmaceutical industry’s comprehensive requirements for analytical performance, data integrity, and standardized laboratory management, PULY introduces the new P90 Series UV-Vis Spectrophotometers.
Built on a high-performance dual-beam optical platform, the P90 Series integrates comprehensive user access control, audit trails, original data protection, and intelligent management functions.
It provides a more complete UV-Vis analytical solution for pharmaceutical QC, drug research and development, and laboratory quality management.
Designed for Pharmaceutical Laboratories
Beyond Accurate Measurement — Built with Data Integrity in Mind
Pharmaceutical laboratories generate large volumes of analytical data every day.
From user login and method creation to sample measurement, data processing, result review, and report generation, every step can affect the authenticity and integrity of the final data.
For this reason, the P90 Series was designed from the outset with data traceability and laboratory process management as one of its core capabilities.
Through user access control, audit trails, and original data protection mechanisms, the system connects:
Users · Methods · Operations · Data · Reports
throughout the complete analytical workflow.
Every analysis therefore provides not only a result, but also a complete record of how that result was generated.
Audit Trail
Critical Operations Recorded Throughout the Process
To meet the data integrity requirements of pharmaceutical laboratories, the P90 Series provides comprehensive audit trail functionality that records critical operations throughout the analytical process.
Continuous Audit Trail
The system automatically generates records for important operations.
Regular operators cannot arbitrarily disable the audit trail, nor can they freely delete or modify audit logs that have already been generated.
This helps reduce data risks associated with unauthorized modification or unrecorded operations.
Individual User Account Management
Independent user accounts can be created for different personnel, with permissions assigned according to individual job responsibilities.
Each operation can be associated with:
User ID / User Name User Role / Operation Time
This establishes a clear link between each user and each laboratory activity.
Enabling true traceability:
Who performed the operation · Recorded
Who made the change · Traceable
Who reviewed the result · Documented
Full-Process Audit Trail
From Login to Final Report — Critical Steps Are Never Missed
AUDIT TRAIL
User Login → Method Creation → Parameter Modification → Sample Measurement → Data Storage → Report Review → Data Archiving
The P90 Series audit trail is not limited to sample measurements. It covers multiple critical stages throughout the complete laboratory workflow.
System Management
Records critical operations including user login and logout, permission changes, instrument calibration, system upgrades, and instrument communication.
Method Management
The creation, modification, locking, and deletion of analytical methods are recorded.
When critical parameters are changed, the corresponding modification information can also be documented, making changes to analytical methods more transparent and traceable.
Sample Measurement
Operations including sample information entry, blank acquisition, spectral scanning, repeat testing, and experiment termination can all be included in the audit trail.
Report Management
Critical processes such as report generation, export, printing, review, and electronic signatures can be recorded accordingly.
Making the entire laboratory workflow clearer, more complete, and fully verifiable.
Original Data Protection
Repeat Testing Without Overwriting Historical Results
NO OVERWRITE TRACEABLE
Original Data 01 → Retest Data 02 → Retest Data 03
Independently Stored · Historical Data Retained
In pharmaceutical laboratories, original data is an essential part of the analytical record.
When a sample needs to be rescanned or retested, the P90 Series can generate a new experimental data file while retaining previously generated results.
New test results do not directly overwrite existing original data.
Data generated at different times can be stored separately, ensuring that every test performed during the analytical process remains traceable.
Audit logs can also be searched using information such as time, user, sample ID, and analytical method. Data export and archiving are supported, providing greater convenience for long-term laboratory data management.
High-Performance Dual-Beam Optical System
A Reliable Data Foundation for Pharmaceutical Analysis

If data integrity determines whether the analytical process can be trusted, stable and accurate optical performance provides the foundation for reliable analytical results.
The P90 Series features a high-performance dual-beam optical system, combined with a holographic diffraction grating, high-performance light sources, and silicon photodiode detectors.
Performance has been further enhanced across critical parameters including wavelength accuracy, wavelength repeatability, stray light, and baseline stability.
190–1100 nm
Wide Wavelength Range
Covers both ultraviolet and visible regions, meeting the requirements of a wide range of pharmaceutical analysis and scientific research applications.
±0.2 nm
Wavelength Accuracy
Provides reliable wavelength positioning for qualitative, quantitative, and spectral analysis of pharmaceutical samples.
≤0.1 nm
Wavelength Repeatability
Improves data consistency across repeated measurements.
≤0.01%T
Low Stray Light
Reduces the influence of stray light on the measurement of high-absorbance samples.
The system also provides:
Photometric Repeatability ≤0.001 A Baseline Drift ≤0.001 A/h
Multiple spectral bandwidth and scanning speed settings are supported, allowing measurement conditions to be flexibly configured for different analytical tasks.
Comprehensive Intelligent Functions for Diverse Testing Applications
Comprehensive functionality and broad compatibility enable applications across pharmaceuticals, chemicals, food, environmental testing, scientific research, and more, providing an integrated solution for diverse testing needs.
Accurate Routine Measurement
Supports three core photometric measurements—transmittance, absorbance, and light source energy—suitable for routine qualitative and quantitative sample screening.
Professional Quantitative Analysis
Built-in coefficient and standard curve methods enable rapid and accurate concentration calculations for known and unknown samples, supporting quantitative analysis in pharmaceutical, food, and other applications.
Multi-Dimensional Spectral Analysis
Supports customizable wavelength scanning and time-kinetics scanning. Continuous spectra and dynamic response curves can be generated, while multiple spectra can be displayed simultaneously for convenient comparison and analysis.
Dedicated Analytical Functions
Includes dedicated DNA/protein analysis functionality and supports multi-wavelength measurements. Multiple sample parameters can be collected in a single workflow, significantly improving analytical efficiency.
Intelligent Management
Improving Everyday Laboratory Efficiency
While meeting professional analytical requirements, the P90 Series also enhances day-to-day instrument operation and maintenance.
Intelligent Light Source Management
The switching wavelength between the deuterium and tungsten lamps can be freely adjusted. Lamp operating life is displayed in real time, and the lamp timer can be reset with one touch after replacement, helping prevent unnecessary lamp consumption and extend instrument service life.
Multi-Device Connectivity and Control
Compatible with wireless communication technologies including Wi-Fi and Bluetooth. Supports operation from smartphones and tablets, enabling remote experiment control and data viewing without being restricted to the instrument itself.
Intelligent Operation and Maintenance
Supports real-time instrument status uploading and proactive fault reporting. Firmware can be updated online with one click, without dismantling the instrument, making future upgrades and maintenance easier and more efficient.
User-Friendly Interaction
A multilingual operating system and intuitive interface help new users get started quickly. One-touch data forwarding and fast report sharing also facilitate team collaboration and remote review.
Extensive Accessory Options
Meeting Diverse Testing Requirements in Pharmaceutical Laboratories
For different samples and experimental requirements, the P90 Series can be expanded with a variety of accessories:
Automatic Sample Holder
Designed for batch sample testing
Thermostatted Cell Holder
Suitable for experiments requiring controlled temperatures
Solid Sample Holder
Extends spectral analysis capabilities to solid samples
Integrating Sphere
Suitable for optical measurement of special materials and samples
Multifunctional Autosampler
Further improves batch testing efficiency
Flexible accessory configurations allow a single instrument to accommodate a broader range of pharmaceutical QC and R&D applications.
P90 SERIES
Designed for Pharmaceutical Laboratories Upgraded Performance and Compliance

Compliance Confidence
Full-process audit trails record critical operations throughout the workflow, meeting GMP / 21 CFR Part 11 regulatory requirements and supporting readiness for unannounced inspections and special compliance reviews.
Data Authenticity
Original spectra are retained without being overwritten, operational changes remain traceable, and accurate, reliable timestamps fully align with ALCOA+ data integrity principles.
Top-Tier Performance
Imported optical components combined with a dual-beam optical system deliver high accuracy, low drift, and excellent reproducibility for precise and reliable measurement data.
Intelligent Efficiency
Multi-device connectivity, intelligent maintenance, and one-touch report generation significantly improve laboratory testing efficiency.
Broad Application Coverage
Covers pharmaceutical QC, scientific research and R&D, food and environmental testing, chemical quality control, and other industry applications.
For pharmaceutical laboratories, reliable analytical data requires more than an accurate result.
It must also answer:
Who generated the data?
Which analytical method was used?
Were any changes made during the process?
Is the original data still retained?
Can the entire analytical process be fully traced?
These are also the core concerns addressed by the P90 Series.
The PULY P90 Series UV-Vis Spectrophotometers combine a high-performance dual-beam optical platform for reliable analytical performance with audit trail and data management capabilities for enhanced laboratory process control.
From accurate measurement to data integrity management, the P90 Series provides a more complete UV-Vis analytical solution for pharmaceutical QC, drug research and development, and laboratory quality control.