V30 / UV30 Spectrophotometers

Single-beam spectrophotometer for education and QC laboratories, with a 128 × 64 dot LCD and 2.0 nm bandwidth (4.0 nm optional).
Series overview
The 30 Series spectrophotometers are designed for education and quality control (QC) laboratories. Standard curves can be generated using single- or dual-wavelength measurements.
Features
- High-performance optical and electronic systems
- Low noise and low stray light
- Large LCD (128 × 64 dots) with curve display capability
- High-quality grating, detector, and lamps
- Data and curves can be stored in real time
- Automatic wavelength setting and blanking
- Independent lamp on/off control
- Easy replacement of pre-aligned lamps
- Reinforced baseplate and bracket ensure durability
Technical specifications
| Parameter | V30 | UV30 |
|---|---|---|
| Wavelength range | 320–1100 nm | 190–1100 nm |
| Spectral bandwidth | 2.0 nm (4.0 nm optional) | 2.0 nm (4.0 nm optional) |
| Optical system | Single beam; blazed holographic grating (1200 lines/mm) | Single beam; blazed holographic grating (1200 lines/mm) |
| Wavelength accuracy | ±0.5 nm | ±0.5 nm |
| Wavelength repeatability | ≤0.2 nm | ≤0.2 nm |
| Wavelength setting | Automatic, 0.1 nm resolution | Automatic, 0.1 nm resolution |
| Photometric range | 0–200 %T; −0.3 to 3 A; 0–9999 C | 0–200 %T; −0.3 to 3 A; 0–9999 C |
| Photometric accuracy | ±0.002 A (0–0.5 A); ±0.004 A (0.5–1 A); ±0.3 %T (0–100 %T) | ±0.002 A (0–0.5 A); ±0.004 A (0.5–1 A); ±0.3 %T (0–100 %T) |
| Photometric repeatability | ≤0.001 A (0–0.5 A); ≤0.002 A (0.5–1 A); ≤0.15 %T (0–100 %T) | ≤0.001 A (0–0.5 A); ≤0.002 A (0.5–1 A); ≤0.15 %T (0–100 %T) |
| Stray light | ≤0.05 %T (220 / 360 nm) | ≤0.05 %T (220 / 360 nm) |
| Scan speed | High, medium, low; maximum 2000 nm/min | High, medium, low; maximum 2000 nm/min |
| Baseline flatness | ±0.002 A | ±0.002 A |
| Stability | ±0.002 A/h (500 nm, 0 A) | ±0.002 A/h (500 nm, 0 A) |
| Noise | ≤0.2 %T / 3 min (250 / 500 nm, 0 %T); ≤0.5 %T / 3 min (250 / 500 nm, 100 %T) | ≤0.2 %T / 3 min (250 / 500 nm, 0 %T); ≤0.5 %T / 3 min (250 / 500 nm, 100 %T) |
| Sample compartment | Accommodates cuvettes with 5–100 mm path lengths | Accommodates cuvettes with 5–100 mm path lengths |
| Detector | Silicon photodiode | Silicon photodiode |
| Lamps | Tungsten Lamp | Pre-aligned tungsten and deuterium lamps |
| Display | Graphic LCD (128 × 64 dots) | Graphic LCD (128 × 64 dots) |
| Keypad | 22-key numeric membrane keypad | 22-key numeric membrane keypad |
| Interfaces | USB and RS-232 | USB and RS-232 |
| Printer | Mini printer or PC printer (optional) | Mini printer or PC printer (optional) |
| PC software | Optional PC software | Optional PC software |
| Power requirements | AC 90–250 V, 50/60 Hz | AC 90–250 V, 50/60 Hz |
| Dimensions | 460 × 360 × 210 mm | 460 × 360 × 210 mm |
| Weight | 16 kg | 18 kg |